Product Description
ÖLFLEX® EB CY
ÖLFLEX® 500 P
ÖLFLEX® 150 CY
Screened and oil-resistant multi-standard cable with H05VVC4V5-K and AWM approval
Wide application range due to multiple approvals
- Oil-resistant according to EN 50363-4-1: TM5
- Harmonised (HAR): H05VVC4V5-K and UL recognized
- EMC-compliant
SKU: 100000021
Categories: CABLES & ACCESSORIES, Power and control cables, PVC sheath - approved, Various applications
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
ÖLFLEX® 150 CY | |||||||
Lapp 0015602 | ÖLFLEX 150 CY 2 X 0,75 | ||||||
2 X 0,75 | 8,5 | 40.0 | 109 | ||||
Lapp 0015603 | ÖLFLEX 150 CY 3 G 0,75 | ||||||
3 G 0,75 | 8,9 | 51.0 | 125 | ||||
Lapp 0015604 | ÖLFLEX 150 CY 4 G 0,75 | ||||||
4 G 0,75 | 9,6 | 70.0 | 157 | ||||
Lapp 0015605 | ÖLFLEX 150 CY 5 G 0,75 | ||||||
5 G 0,75 | 10,3 | 77.0 | 180 | ||||
Lapp 0015607 | ÖLFLEX 150 CY 7 G 0,75 | ||||||
7 G 0,75 | 12,3 | 93.0 | 226 | ||||
Lapp 0015612 | ÖLFLEX 150 CY 12 G 0,75 | ||||||
12 G 0,75 | 14,8 | 155.0 | 325 | ||||
Lapp 0015702 | ÖLFLEX 150 CY 2 X 1,0 | ||||||
2 X 1,0 | 8,8 | 46.4 | 121 | ||||
Lapp 0015703 | ÖLFLEX 150 CY 3 G 1,0 | ||||||
3 G 1,0 | 9,4 | 76.0 | 145 | ||||
Lapp 0015704 | ÖLFLEX 150 CY 4 G 1,0 | ||||||
4 G 1,0 | 10.0 | 80.0 | 180 | ||||
Lapp 0015705 | ÖLFLEX 150 CY 5 G 1,0 | ||||||
5 G 1,0 | 11.0 | 95.0 | 203 | ||||
Lapp 0015707 | ÖLFLEX 150 CY 7 G 1,0 | ||||||
7 G 1,0 | 13.0 | 118.0 | 273 | ||||
Lapp 0015712 | ÖLFLEX 150 CY 12 G 1,0 | ||||||
12 G 1,0 | 15,6 | 195.0 | 425 | ||||
Lapp 0015802 | ÖLFLEX 150 CY 2 X 1,5 | ||||||
2 X 1,5 | 10.0 | 59.2 | 151 | ||||
Lapp 0015803 | ÖLFLEX 150 CY 3 G 1,5 | ||||||
3 G 1,5 | 10,5 | 84.0 | 159 | ||||
Lapp 0015804 | ÖLFLEX 150 CY 4 G 1,5 | ||||||
4 G 1,5 | 11,4 | 94.8 | 211 | ||||
Lapp 0015805 | ÖLFLEX 150 CY 5 G 1,5 | ||||||
5 G 1,5 | 12,7 | 122.0 | 241 | ||||
Lapp 0015807 | ÖLFLEX 150 CY 7 G 1,5 | ||||||
7 G 1,5 | 15,1 | 143.0 | 306 | ||||
Lapp 0015812 | ÖLFLEX 150 CY 12 G 1,5 | ||||||
12 G 1,5 | 17,8 | 254.0 | 480 | ||||
Lapp 0015903 | ÖLFLEX 150 CY 3 G 2,5 | ||||||
3 G 2,5 | 11,9 | 120.0 | 245 | ||||
Lapp 0015904 | ÖLFLEX 150 CY 4 G 2,5 | ||||||
4 G 2,5 | 13,2 | 170.0 | 295 | ||||
Lapp 0015905 | ÖLFLEX 150 CY 5 G 2,5 | ||||||
5 G 2,5 | 14,7 | 205.0 | 365 | ||||
Lapp 0015907 | ÖLFLEX 150 CY 7 G 2,5 | ||||||
7 G 2,5 | 17,5 | 241.0 | 480 |
Application range
- Plant engineering
Industrial machinery
Heating and air-conditioning systems - In EMC-sensitive environments
(electromagnetic compatibility) - Mainly used in dry, damp and wet interiors (including water-oil mixtures), but not for outdoor use
- For fixed installation under medium mechanical load conditions, and applications with occasional flexing at free, non-continuously recurring movement without tensile load or compulsory guidance
- Note: for the use of AWM (Appliance Wiring Material) cables in industrial machinery (USA) according to NFPA 79 Ed. 2012: please see the catalogue appendix table T29
Benefits
- Wide application range due to multiple approvals
Product Make-up
- Fine-wire strand made of bare copper wires
- PVC core insulation
- PVC inner sheath, grey
- Tinned-copper braiding
- PVC outer sheath, high oil-resistance, grey (RAL 7001)
Norm references / Approvals
- H05VVC4V5-K (EN 50525-2-51)
- UL AWM Style 21098 or 2587
CSA AWM I A/B II A/B - Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related secondary size the cross-section of the conductor mostly works out to be greater than the
specified nominal value.
Product features
- Flame-retardant according to IEC 60332-1-2
and UL 1581 §1061 Cable Flame Test - Oil-resistant according to EN 50363-4-1: TM5
- High degree of screening
low transfer impedance
(max. 250 ?/km at 30 MHz)
Core identification code | Black with white numbers acc. to VDE 0293-1 |
Classification | ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable |
Conductor stranding | Fine wire according to VDE 0295, class 5/IEC 60228 class 5 |
Minimum bending radius | Occasional flexing: 20 x outer diameter Fixed installation: 6 x outer diameter |
Nominal voltage | HAR U0/U: 300/500 V UL/CSA: 600 V |
Test voltage | 3000 V |
Protective conductor | G = with GN-YE protective conductor X = without protective conductor |
Temperature range | Occasional flexing: HAR: -5°C to +70°C UL/CSA: -5°C to +90°C Fixed installation: HAR: -40°C to +70°C UL/CSA: -40°C to +90°C |