Product Description
ÖLFLEX® ROBUST 210
ÖLFLEX® CLASSIC 100 YELLOW
Yellow outer sheath for special warning purposes
High electrical performance due to 4 kV test voltage
- For warning purposes
SKU: 100000002
Categories: CABLES & ACCESSORIES, Power and control cables, PVC outer sheath and coloured cores, Various applications
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
ÖLFLEX® CLASSIC 100 YELLOW; U0/U: 450/750 V | |||||||
Lapp 0010400 | ÖLFLEX CLASSIC 100 YELLOW 3 G 1,5 | ||||||
3 G 1,5 | 8,1 | 43.0 | 95 | ||||
Lapp 00104023 | ÖLFLEX CLASSIC 100 YELLOW 4 G 1,5 | ||||||
4 G 1,5 | 8,9 | 58.0 | 117 | ||||
Lapp 00104033 | ÖLFLEX CLASSIC 100 YELLOW 5 G 1,5 | ||||||
5 G 1,5 | 10.0 | 72.0 | 144 | ||||
Lapp 0010401 | ÖLFLEX CLASSIC 100 YELLOW 3 G 2,5 | ||||||
3 G 2,5 | 9,6 | 72.0 | 152 | ||||
Lapp 00104043 | ÖLFLEX CLASSIC 100 YELLOW 4 G 2,5 | ||||||
4 G 2,5 | 10,7 | 96.0 | 205 | ||||
Lapp 00104053 | ÖLFLEX CLASSIC 100 YELLOW 5 G 2,5 | ||||||
5 G 2,5 | 11,8 | 120.0 | 225 |
Application range
- For electrical circuits that remain ‘live’ after the main switch has been disconnected
- Service sockets and illumination circuits
in electrical switchboards and cabinets - Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
Benefits
- High electrical performance due to 4 kV test voltage
Product Make-up
- Fine-wire strand made of bare copper wires
- PVC insulation LAPP P8/1
- PVC outer sheath, yellow (RAL 1016)
Norm references / Approvals
- Based on IEC 60227-5 and EN 50525-2-51
Product features
- Flame-retardant according IEC 60332-1-2
- Good chemical resistance, see catalogue appendix T1
Core identification code | VDE 0293-308, refer to Appendix T9 |
Classification | ETIM 5.0 Class-ID: EC001578 ETIM 5.0 Class-Description: Flexible cable |
Conductor stranding | Fine wire according to VDE 0295, class 5/IEC 60228 class 5 |
Torsion movement in WTG | TW-0 & TW-1, refer to Appendix T0 |
Minimum bending radius | Occasional flexing: 15 x outer diameter Fixed installation: 4 x outer diameter |
Nominal voltage | U0/U: 450/750 VAC In protected and fixed installations: U0/U: 600/1000 V |
Test voltage | 4000 V |
Protective conductor | G = with GN-YE protective conductor X = without protective conductor |
Temperature range | Occasional flexing: -5°C to +70°C Fixed installation: -40°C to +80°C |