Product Description
UNITRONIC® LiYCY
UNITRONIC® BUS ASI FD
JE-LiYCY…BD
Screened data transmission cable for industrial electronics
Can be used for Maxi TERMI-POINT® wiring; Overall braid minimises electrical
interference; Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
- In accordance with DIN VDE 0815
SKU: 100000279
Categories: CABLES & ACCESSORIES, Data communication systems, Installation cable for industrial electronics, Low frequency data transmission cables
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of pairs and conductor cross section (mm²) | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
JE-LiYCY…BD | |||||||
Lapp 0034200 | JE-LiYCY…BD 2 x 2 x 0,5 | ||||||
2 x 2 x 0,5 | 7.5 | 51.0 | 70 | ||||
Lapp 0034201 | JE-LiYCY…BD 4 x 2 x 0,5 | ||||||
4 x 2 x 0,5 | 10.0 | 87.0 | 155 | ||||
Lapp 0034202 | JE-LiYCY…BD 8 x 2 x 0,5 | ||||||
8 x 2 x 0,5 | 13.0 | 144.0 | 260 | ||||
Lapp 0034208 | JE-LiYCY…BD 12 x 2 x 0,5 | ||||||
12 x 2 x 0,5 | 15.5 | 195.0 | 340 | ||||
Lapp 0034203 | JE-LiYCY…BD 16 x 2 x 0,5 | ||||||
16 x 2 x 0,5 | 17.0 | 249.0 | 430 | ||||
Lapp 0034210 | JE-LiYCY…BD 20 x 2 x 0,5 | ||||||
20 x 2 x 0,5 | 18.5 | 298.0 | 495 | ||||
Lapp 0034204 | JE-LiYCY…BD 24 x 2 x 0,5 | ||||||
24 x 2 x 0,5 | 20.5 | 348.0 | 605 | ||||
Lapp 0034212 | JE-LiYCY…BD 32 x 2 x 0,5 | ||||||
32 x 2 x 0,5 | 22.5 | 441.0 | 738 |
Application range
- Connection cable for use in electronics and in measurement, control and signal applications
- This cable is also used as a pulse and data transmission cable
- JE-LiYCY…BD has also proved to be an efficient connection cable for telephone systems, e.g. paging and intercom systems.
- For fixed installation on and under plaster, in dry and damp rooms
- For outdoor use this cable should be installed under plaster only
Benefits
- Can be used for Maxi TERMI-POINT® wiring
- Overall braid minimises electrical
interference - Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
Product Make-up
- 7-wire bare stranded copper conductor
- Core insulation made of PVC
- 2 cores twisted into a pair, and 4 pairs into units (for 2 x 2 x 0.5 as star quad cable)
- Bundles twisted in layers,
foil wrapping,
screening braid made of tinned copper wires - Outer sheath made of PVC
Outer sheath colour: pebble grey (RAL 7032)
Norm references / Approvals
- In accordance with DIN VDE 0815
type JE-LiYCY…BD
Product features
- The 2-pair version (2 x 2 x 0.5) is twisted into a star quad
- Flame-retardant according IEC 60332-1-2
- JE-LiYCY…BD EB
Blue version for intrinsically safe cirsuits: Complies with VDE 0165 Section 12.2.2.6. Marking of cables for hazard type -i- (intrinsically safe) is specified
Core identification code | according to VDE 0815, refer to Appendix T10 |
Mutual capacitance | max. 100 nF/km |
Peak operating voltage | (not for power applications) 225 V |
Classification | ETIM 5.0 Class-ID: EC000829 ETIM 5.0 Class-Description: Control cable |
Inductivity | approx. 0.65 mH/km |
Coupling | approx. 200 pF/100 m |
Conductor stranding | Multi-wire, 7 x 0.3mm |
Minimum bending radius | Occasional flexing: 15 x outer diameter Fixed installation: 5 x outer diameter |
Test voltage | Core/core: 500 V Core/screen: 2000 V |
Loop resistance | max. 78.4 ohm/km |
Temperature range | Occasional flexing: -5°C to +50°C Fixed installation: -30°C to +70°C |