Product Description
Socket outlet CEE 3-way 230V
RD-Y(ST)Y
UNITRONIC® LiYCY (TP)
Screened data transmission cable with colour code acc. to DIN 47100 and twisted pairs
Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects); Overall braid minimises electrical
interference
- TP = twisted pair
SKU: 100000245
Categories: CABLES & ACCESSORIES, Data communication systems, DIN colour code, Low frequency data transmission cables
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of pairs and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
UNITRONIC® LiYCY (TP) | |||||||
Lapp 0035131 | UNITRONIC LiYCY (TP) 2 x 2 x 0,14 | ||||||
2 x 2 x 0,14 | 5.3 | 18.5 | 39 | ||||
Lapp 0035141 | UNITRONIC LiYCY (TP) 3 x 2 x 0,14 | ||||||
3 x 2 x 0,14 | 5.8 | 23.0 | 48 | ||||
Lapp 0035132 | UNITRONIC LiYCY (TP) 4 x 2 x 0,14 | ||||||
4 x 2 x 0,14 | 6.2 | 26.6 | 54 | ||||
Lapp 0035133 | UNITRONIC LiYCY (TP) 6 x 2 x 0,14 | ||||||
6 x 2 x 0,14 | 7.1 | 48.5 | 85 | ||||
Lapp 0035150 | UNITRONIC LiYCY (TP) 8 x 2 x 0,14 | ||||||
8 x 2 x 0,14 | 8.2 | 53.7 | 97 | ||||
Lapp 0035134 | UNITRONIC LiYCY (TP) 10 x 2 x 0,14 | ||||||
10 x 2 x 0,14 | 8.7 | 59.0 | 110 | ||||
Lapp 0035135 | UNITRONIC LiYCY (TP) 12 x 2 x 0,14 | ||||||
12 x 2 x 0,14 | 8.9 | 66.0 | 142 | ||||
Lapp 0035136 | UNITRONIC LiYCY (TP) 16 x 2 x 0,14 | ||||||
16 x 2 x 0,14 | 10.2 | 79.0 | 154 | ||||
Lapp 0035142 | UNITRONIC LiYCY (TP) 20 x 2 x 0,14 | ||||||
20 x 2 x 0,14 | 11.3 | 97.0 | 184 | ||||
Lapp 0035137 | UNITRONIC LiYCY (TP) 25 x 2 x 0,14 | ||||||
25 x 2 x 0,14 | 12.5 | 113.0 | 238 | ||||
Lapp 0035800 | UNITRONIC LiYCY (TP) 2 x 2 x 0,25 | ||||||
2 x 2 x 0,25 | 6.3 | 28.0 | 54 | ||||
Lapp 0035801 | UNITRONIC LiYCY (TP) 3 x 2 x 0,25 | ||||||
3 x 2 x 0,25 | 7.1 | 39.6 | 68.5 | ||||
Lapp 0035802 | UNITRONIC LiYCY (TP) 4 x 2 x 0,25 | ||||||
4 x 2 x 0,25 | 7.6 | 44.9 | 81 | ||||
Lapp 0035803 | UNITRONIC LiYCY (TP) 6 x 2 x 0,25 | ||||||
6 x 2 x 0,25 | 8.5 | 69.5 | 115 | ||||
Lapp 0035804 | UNITRONIC LiYCY (TP) 8 x 2 x 0,25 | ||||||
8 x 2 x 0,25 | 10.3 | 76.9 | 130 | ||||
Lapp 0035805 | UNITRONIC LiYCY (TP) 10 x 2 x 0,25 | ||||||
10 x 2 x 0,25 | 11.0 | 102.0 | 158 | ||||
Lapp 0035806 | UNITRONIC LiYCY (TP) 12 x 2 x 0,25 | ||||||
12 x 2 x 0,25 | 11.3 | 120.0 | 190 | ||||
Lapp 0035807 | UNITRONIC LiYCY (TP) 16 x 2 x 0,25 | ||||||
16 x 2 x 0,25 | 12.5 | 146.5 | 238 | ||||
Lapp 0035808 | UNITRONIC LiYCY (TP) 25 x 2 x 0,25 | ||||||
25 x 2 x 0,25 | 16.1 | 205.0 | 344 | ||||
Lapp 0035810 | UNITRONIC LiYCY (TP) 2 x 2 x 0,5 | ||||||
2 x 2 x 0,5 | 7.9 | 48.1 | 93 | ||||
Lapp 0035811 | UNITRONIC LiYCY (TP) 3 x 2 x 0,5 | ||||||
3 x 2 x 0,5 | 8.7 | 73.7 | 129 | ||||
Lapp 0035812 | UNITRONIC LiYCY (TP) 4 x 2 x 0,5 | ||||||
4 x 2 x 0,5 | 9.4 | 82.0 | 146 | ||||
Lapp 0035813 | UNITRONIC LiYCY (TP) 6 x 2 x 0,5 | ||||||
6 x 2 x 0,5 | 11.1 | 110.0 | 198 | ||||
Lapp 0035814 | UNITRONIC LiYCY (TP) 8 x 2 x 0,5 | ||||||
8 x 2 x 0,5 | 13.1 | 139.0 | 259 | ||||
Lapp 0035816 | UNITRONIC LiYCY (TP) 12 x 2 x 0,5 | ||||||
12 x 2 x 0,5 | 14.9 | 198.3 | 354 | ||||
Lapp 0035817 | UNITRONIC LiYCY (TP) 16 x 2 x 0,5 | ||||||
16 x 2 x 0,5 | 16.5 | 240.0 | 459 | ||||
Lapp 0035820 | UNITRONIC LiYCY (TP) 2 x 2 x 0,75 | ||||||
2 x 2 x 0,75 | 8.5 | 58.0 | 106 | ||||
Lapp 0035821 | UNITRONIC LiYCY (TP) 3 x 2 x 0,75 | ||||||
3 x 2 x 0,75 | 9.4 | 84.0 | 140 | ||||
Lapp 0035822 | UNITRONIC LiYCY (TP) 4 x 2 x 0,75 | ||||||
4 x 2 x 0,75 | 10.7 | 108.0 | 179 | ||||
Lapp 0035827 | UNITRONIC LiYCY (TP) 5 x 2 x 0,75 | ||||||
5 x 2 x 0,75 | 11.1 | 126.0 | 215 | ||||
Lapp 0035823 | UNITRONIC LiYCY (TP) 6 x 2 x 0,75 | ||||||
6 x 2 x 0,75 | 12.1 | 146.0 | 246 | ||||
Lapp 0035824 | UNITRONIC LiYCY (TP) 8 x 2 x 0,75 | ||||||
8 x 2 x 0,75 | 14.7 | 180.0 | 305 | ||||
Lapp 0035825 | UNITRONIC LiYCY (TP) 12 x 2 x 0,75 | ||||||
12 x 2 x 0,75 | 16.2 | 261.0 | 456 | ||||
Lapp 0035830 | UNITRONIC LiYCY (TP) 2 x 2 x 1 | ||||||
2 x 2 x 1 | 9.0 | 84.0 | 142 | ||||
Lapp 0035831 | UNITRONIC LiYCY (TP) 3 x 2 x 1 | ||||||
3 x 2 x 1 | 10.4 | 96.0 | 173 | ||||
Lapp 0035832 | UNITRONIC LiYCY (TP) 4 x 2 x 1 | ||||||
4 x 2 x 1 | 11.3 | 121.0 | 212 | ||||
Lapp 0035836 | UNITRONIC LiYCY (TP) 5 x 2 x 1 | ||||||
5 x 2 x 1 | 11.8 | 161.0 | 266 |
Application range
- Can be used multifunctional in electronics of computer systems, electronic control equipment, office machines, balances, etc.
- Dry or damp rooms
Benefits
- Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects) - Overall braid minimises electrical
interference
Product Make-up
- Fine-wire strand made of bare copper wires
- Core insulation made of PVC
- TP structure
- Tinned-copper braiding
- Outer sheath made of PVC
Outer sheath colour: pebble grey (RAL 7032)
Norm references / Approvals
- Based on VDE 0812
Product features
- Good protection against capacitive interference from electric fields (e.g. power cable)
- Flame-retardant according IEC 60332-1-2
Core identification code | DIN 47100, refer to Appendix T9 |
Mutual capacitance | C/C: approx. 120 nF/km C/S: approx. 160 nF/km |
Peak operating voltage | (not for power applications) at 0.14 mm²: 350 V at ? 0.25 mm²: 500 V |
Classification | ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable |
Inductivity | Approx. 0.50 mH/km |
Conductor stranding | Fine copper wire strands |
Minimum bending radius | Occasional flexing: 15 x outer diameter Fixed installation: 6 x outer diameter |
Test voltage | At 0.14 mm²: 1200 V ? 0.25 mm²: 1500 V |
Temperature range | Occasional flexing: -5°C to +70°C Fixed installation: -40°C to +80°C |