Product Description
A-2YF(L)2Y...ST III BD Outdoor Cable
UNITRONIC® BUS IBS FD P
UNITRONIC® BUS PB FD P HYBRID
Highly flexible application
For use where the combination of a halogen-free outer sheath with properties similar to PUR and enhanced flame-retardance is required; For highly flexible applications (power chains, moving machine parts); Cables can be used for PROFIBUS-DP as well as PROFIBUS-FMS and FIP
SKU: 100000306
Categories: CABLES & ACCESSORIES, Cables for bus systems PROFIBUS-DP/FMS/FIP, Characteristic impedance: 135 - 165 ohm, Data communication systems
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||||
---|---|---|---|---|---|---|---|---|---|
Article designation | Number of pairs and conductor diameter (mm) | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | |||||
Highly flexible application | |||||||||
Lapp 2170495 | UNITRONIC BUS PB FD P HYBRID | ||||||||
UNITRONIC® BUS PB FD P HYBRID | 1 x 2 x 0.64 Ø + 4 x 1.5 mm² | 11.3 | 89.0 | 148 |
Application range
- PROFIBUS DP (in accordance with DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also suitable for FIP – Factory Instrumentation Protocol).
Benefits
- For use where the combination of a halogen-free outer sheath with properties similar to PUR and enhanced flame-retardance is required
- For highly flexible applications (power chains, moving machine parts)
- Cables can be used for PROFIBUS-DP as well as PROFIBUS-FMS and FIP
Product Make-up
- Cores for Power Supply
4 x 1.5 mm² (AWG16)
Product features
- HYBRID: cable for data transmission + power supply
- Flame-retardant according IEC 60332-1-2
- Oil-resistant
Mutual capacitance | (800 Hz): max. 30 nF/km |
Peak operating voltage | (not for power applications) 100 V |
Minimum bending radius | Flexing: 15 x outer diameter |
Test voltage | Core/core: 600 V Core/screen: 600 V |
Temperature range | Flexing: -30°C to +60°C Fixed installation: -40°C to +70°C |
Characteristic impedance | 150 ± 15 Ohm |