Product Description
UNITRONIC® 300 / UNITRONIC® 300 S
UNITRONIC® BUS PB FD P HYBRID
UNITRONIC® BUS ASI FD
Highly flexible application
The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5; For highly flexible applications (power chains, moving machine parts); High oil-resistance
- “FD” = suitable for power chains
- LD = Long Distance
SKU: 100000289
Categories: CABLES & ACCESSORIES, Cables for bus system AS-INTERFACE, Data communication systems, Sensor/actuator communication
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Article designation | Outer sheath material | Outer sheath colour | Application | Number of cores and mm² per conductor | Copper index (kg/km) | Weight (kg/km) | |||||||
For highly flexible applications (power chains, moving machine parts) | |||||||||||||
Lapp 2170357 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI FD P FRNC | PUR UL/CSA (AWM) | yellow | Data and power transmission | 2 x 1,5 | 29.0 | 64 | |||||||
Lapp 2170358 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI FD P FRNC | PUR UL/CSA (AWM) | black | Transmission of 30 V DC auxiliary power | 2 x 1,5 | 29.0 | 64 | |||||||
Lapp 2170317 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI LD FD P | PUR UL/CSA (AWM) | yellow | Data and power transmission | 2 x 2,5 | 48.0 | 74 | |||||||
Lapp 2170318 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI LD FD P | PUR UL/CSA (AWM) | black | Transmission of 30 V DC auxiliary power | 2 x 2,5 | 48.0 | 74 | |||||||
Lapp 2170830 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI FD (TPE) A | TPE UL/CSA (AWM) | yellow | Data and power transmission | 2 x 1,5 | 29.0 | 64 | |||||||
Lapp 2170831 | UNITRONIC BUS ASI FD | ||||||||||||
UNITRONIC® BUS ASI FD (TPE) A | TPE UL/CSA (AWM) | black | Transmission of 30 V DC auxiliary power | 2 x 1,5 | 29.0 | 64 |
Application range
- Communication at sensor/actuator level
- UNITRONIC® Fieldbus
sensor-/actuator wiring
Benefits
- The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5. - For highly flexible applications (power chains, moving machine parts)
- High oil-resistance
Product Make-up
- Extra-fine wire, tinned copper strands
- Core insulation: blue and brown
- Profiled outer sheath: TPE or PUR
- Colour: yellow (RAL 1023) or black (RAL 9005)
Norm references / Approvals
- ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
- TPE variant: UL AWM Style 2103
CSA AWM II A/B - PUR versions: UL AWM Style 20549
Product features
- PUR versions are halogen-free according to IEC 60754-1
- Flame-retardant according to IEC 60332-1-2, UL FT-2 flame test
- Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
- The conductor is contacted by “piercing technology” within the ASI modules.
- The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).
Peak operating voltage | 300 V (not for power applications) |
Conductor resistance | 1.5 mm²: max. 13.7 Ohm/km 2.5 mm²: max. 8.21 Ohm/km |
Minimum bending radius | Fixed installation: 12 mm Flexing without fixing: 24 mm Flexing with fixing: 60 mm (15 x D) |
Test voltage | Core/core: 2000 V |
Temperature range | Fixed installation: -40°C to +80°C (TPE +105°C) Flexing – without fixing: -30 °C to +70 °C (TPE +105 °C) |