Product Description
Socket outlet CEE 5-way 400V
UNITRONIC® FD CP plus
UNITRONIC® Li2YCY (TP)
Screened data transmission cable mit PE core insulation, 7-wire strands and twisted pairs
7-wire stranded conductor (UNITRONIC® Li2YCY (TP) and UNITRONIC® Li2YCYv (TP) can be used for Maxi TERMI-POINT® wiring; Overall braid minimises electrical
interference; Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
- Cables for RS485/RS422
SKU: 100000254
Categories: CABLES & ACCESSORIES, Data communication systems, Low capacitance, Low frequency data transmission cables
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of pairs and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
UNITRONIC® Li2YCY (TP) | |||||||
Lapp 0031320 | UNITRONIC Li2YCY (TP) 2 x 2 x 0,22 | ||||||
2 x 2 x 0,22 | 6.5 | 24.2 | 59 | ||||
Lapp 0031321 | UNITRONIC Li2YCY (TP) 3 x 2 x 0,22 | ||||||
3 x 2 x 0,22 | 7.1 | 28.6 | 66 | ||||
Lapp 0031322 | UNITRONIC Li2YCY (TP) 4 x 2 x 0,22 | ||||||
4 x 2 x 0,22 | 7.3 | 34.2 | 78 | ||||
Lapp 0031323 | UNITRONIC Li2YCY (TP) 8 x 2 x 0,22 | ||||||
8 x 2 x 0,22 | 9.1 | 70.0 | 125 | ||||
Lapp 0031324 | UNITRONIC Li2YCY (TP) 10 x 2 x 0,22 | ||||||
10 x 2 x 0,22 | 10.4 | 76.0 | 143 | ||||
Lapp 0031335 | UNITRONIC Li2YCY (TP) 1 x 2 x 0,34 | ||||||
1 x 2 x 0,34 | 5.8 | 20.0 | 44 | ||||
Lapp 0031325 | UNITRONIC Li2YCY (TP) 2 x 2 x 0,34 | ||||||
2 x 2 x 0,34 | 7.7 | 34.1 | 79 | ||||
Lapp 0031326 | UNITRONIC Li2YCY (TP) 3 x 2 x 0,34 | ||||||
3 x 2 x 0,34 | 8.4 | 43.0 | 89 | ||||
Lapp 0031327 | UNITRONIC Li2YCY (TP) 4 x 2 x 0,34 | ||||||
4 x 2 x 0,34 | 8.7 | 47.0 | 101 | ||||
Lapp 0031328 | UNITRONIC Li2YCY (TP) 8 x 2 x 0,34 | ||||||
8 x 2 x 0,34 | 11.0 | 85.8 | 176 | ||||
Lapp 0031336 | UNITRONIC Li2YCY (TP) 1 x 2 x 0,5 | ||||||
1 x 2 x 0,5 | 6.3 | 29.0 | 53 | ||||
Lapp 0031330 | UNITRONIC Li2YCY (TP) 2 x 2 x 0,5 | ||||||
2 x 2 x 0,5 | 8.5 | 37.0 | 85 | ||||
Lapp 0031331 | UNITRONIC Li2YCY (TP) 3 x 2 x 0,5 | ||||||
3 x 2 x 0,5 | 9.3 | 55.0 | 105 | ||||
Lapp 0031332 | UNITRONIC Li2YCY (TP) 4 x 2 x 0,5 | ||||||
4 x 2 x 0,5 | 9.6 | 60.0 | 122 | ||||
Lapp 0031333 | UNITRONIC Li2YCY (TP) 8 x 2 x 0,5 | ||||||
8 x 2 x 0,5 | 12.7 | 113.3 | 213 | ||||
Lapp 0031334 | UNITRONIC Li2YCY (TP) 10 x 2 x 0,5 | ||||||
10 x 2 x 0,5 | 14.8 | 154.0 | 261 |
Application range
- Particularly suitable for wiring data systems with transmission rates up to 10 Megabits per second, and is qualified for the RS422 and RS485 interfaces.
- For fixed and limited flexible installation
- Can be used in dry or damp rooms
- Signal-, control- and measuring cable,for transmission of low, sensitive signals and high bit rates
- UNITRONIC® Li2YCYv (TP) with reinforced black outer sheath (Yv) is suitable for indoors and outdoors, as well as direct burial in the ground
Benefits
- 7-wire stranded conductor (UNITRONIC® Li2YCY (TP) and UNITRONIC® Li2YCYv (TP) can be used for Maxi TERMI-POINT® wiring
- Overall braid minimises electrical
interference - Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
Product Make-up
- 7-wire bare stranded copper conductor
- Core insulation made of polyethylene (PE)
- TP structure
- Tinned-copper braiding
- Outer sheath made of PVC
Outer sheath colour: pebble grey (RAL 7032)
Norm references / Approvals
- Based on VDE 0812
Product features
- Flame-retardant according IEC 60332-1-2
Core identification code | DIN 47100, refer to Appendix T9 |
Mutual capacitance | At 800 Hz: max. 60 nF/km |
Peak operating voltage | (not for power applications) 250 V |
Classification | ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable |
Inductivity | approx. 0.65 mH/km |
Conductor stranding | Stranded conductor, based on VDE 0881, 7-wire |
Minimum bending radius | Occasional flexing: 15 x outer diameter Fixed installation: 6 x outer diameter |
Short-range crosstalk attenuation | Up to 1 MHz min. 50 dB Up to 10 MHz min. 40 dB |
Test voltage | Core/core: 2000 V Core/screen: 1000 V |
Temperature range | Occasional flexing: -5°C to +70°C Fixed installation: -40°C to +80°C |
Characteristic impedance | 100 ± 15 Ohm (> 1 MHz) |