Product Description
Socket outlet CEE 5-way 400V
UNITRONIC® FD CP plus
UNITRONIC® EB CY (TP)
Screened data transmission cable with twisted pairs and blue outer sheath
Overall braid minimises electrical
interference; Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
- Hazard protection type -i- is required where there is a risk of explosion
![]() |
![]() |
SKU: 100000246
Categories: CABLES & ACCESSORIES, Data communication systems, DIN colour code, Low frequency data transmission cables
Article List
Product description
Technical Data
| Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
|---|---|---|---|---|---|---|---|
| Number of pairs and conductor cross section (mm²) | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
| UNITRONIC® EB CY (TP) | |||||||
| Lapp 0012620 | UNITRONIC EB CY (TP) 2 x 2 x 0,75 | ||||||
| 2 x 2 x 0,75 | 8.7 | 58.0 | 106 | ||||
| Lapp 0012621 | UNITRONIC EB CY (TP) 3 x 2 x 0,75 | ||||||
| 3 x 2 x 0,75 | 9.6 | 84.0 | 140 | ||||
| Lapp 0012622 | UNITRONIC EB CY (TP) 4 x 2 x 0,75 | ||||||
| 4 x 2 x 0,75 | 10.9 | 108.0 | 179 | ||||
| Lapp 0012624 | UNITRONIC EB CY (TP) 6 x 2 x 0,75 | ||||||
| 6 x 2 x 0,75 | 12.3 | 146.0 | 246 | ||||
| Lapp 0012626 | UNITRONIC EB CY (TP) 10 x 2 x 0,75 | ||||||
| 10 x 2 x 0,75 | 16.1 | 220.0 | 392 | ||||
Application range
- Reliable data transmission in intrinsically safe circuits
- In EMC-sensitive environments
(electromagnetic compatibility)
Benefits
- Overall braid minimises electrical
interference - Decoupling of circuits by means of
twisted-pair (TP) design (crosstalk effects)
Product Make-up
- Fine-wire strand made of bare copper wires
- Core insulation made of PVC
- TP structure
- Tinned-copper braiding
- Outer sheath made of PVC
Outer sheath colour: sky blue (RAL 5015)
Norm references / Approvals
- Based on VDE 0812
Product features
- Complies with VDE 0165 Section 12.2.2.6. Marking of cables for hazard type -i- (intrinsically safe) is specified
- Flame-retardant according IEC 60332-1-2
| Core identification code | DIN 47100, refer to Appendix T9 |
| Mutual capacitance | C/C approx. 100 nF/km C/S approx. 140 nF/km |
| Peak operating voltage | (not for power applications) 900 V |
| Classification | ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable |
| Inductivity | approx. 0.65 mH/km |
| Conductor stranding | Strand, fine-wire in accordance with IEC 60228 Cl. 5 |
| Minimum bending radius | Occasional flexing: 15 x outer diameter Fixed installation: 6 x outer diameter |
| Test voltage | 2500 V |
| Temperature range | Occasional flexing: -5°C to +70°C Fixed installation: -40°C to +80°C |




Product information (PDF)