Product Description
ÖLFLEX® CRANE
X07V-K with twin colour helix insulation
ÖLFLEX® HEAT 260 GLS
Steel-armoured PTFE cables for increased mechanical stress
Close-meshed braid made of galvanised steel wires protects against mechanical damage; Small outer diameters for maximum saving of space and weight; Germanischer Lloyd approval for use with ship diesel engines
- Good thermal and mechanical performance
- Robust cable design
- GL – Germanischer Lloyd approved
SKU: 100000150
Categories: CABLES & ACCESSORIES, Expanded ambient temperatures, Power and control cables, PTFE cables (-190°C to +260°C)
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
ÖLFLEX® HEAT 260 GLS | |||||||
Lapp 0091120 | ÖLFLEX HEAT 260 GLS 2 X 1,5 | ||||||
2 X 1,5 | 5,7 | 29.0 | 93 | ||||
Lapp 0091121 | ÖLFLEX HEAT 260 GLS 3 G 1,5 | ||||||
3 G 1,5 | 6,1 | 43.0 | 102 | ||||
Lapp 00911223 | ÖLFLEX HEAT 260 GLS 4 G 1,5 | ||||||
4 G 1,5 | 6,6 | 58.0 | 130 | ||||
Lapp 00911233 | ÖLFLEX HEAT 260 GLS 5 G 1,5 | ||||||
5 G 1,5 | 7,3 | 72.0 | 149 | ||||
Lapp 0091124 | ÖLFLEX HEAT 260 GLS 7 G 1,5 | ||||||
7 G 1,5 | 8.0 | 101.0 | 180 |
Application range
- Extremely high temperatures and mechanical stress require special insulated and armoured cables
- Main applications
– Ship-building
– Signal systems
– Monitoring devices
– Diesel engines
– Steam boiler units
– Turbine manufacturing
Benefits
- Close-meshed braid made of galvanised steel wires protects against mechanical damage
- Small outer diameters for maximum saving of space and weight
- Germanischer Lloyd approval for use with ship diesel engines
Product Make-up
- Fine-wire strand made of nickel-plated copper
- PTFE-based core insulation
- Cores twisted together
- Impregnated glass fibre braiding
- Galvanised steel wire braiding
Norm references / Approvals
- GL – Germanischer Lloyd approved
Product features
- Flame-retardant
- Stress crack resistant to frequent ambient temperature fluctuations
- High dielectric strength and high abrasion resistance
- High elongation resistance and tear strength
- Only suitable for use in dry conditions
Core identification code | Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9 7-core version: gn/ye, bl, bn, bk, bk, bk, tr |
Classification | ETIM 5.0 Class-ID: EC001578 ETIM 5.0 Class-Description: Flexible cable |
Conductor stranding | Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5 |
Minimum bending radius | In fixed installations: 5 x cable diameter |
Nominal voltage | U0/U 300/500 V according to GL: 250 V |
Test voltage | 1500 V |
Protective conductor | G = with GN-YE protective conductor X = without protective conductor |
Temperature range | Fixed installation: -190°C to +260°C According to GL: +205 °C |