Product Description
ÖLFLEX® TORSION D FRNC
Screened, cold and oil-resistant cables for flexible applications under torsional load, halogen-free – 0.6/1 kV
The special design reliably compensates for the permanent torsional drip loop movements inside the wind turbine between the nacelle and the tower; The high flexibility and good dismantling
and stripping properties enable easy space-
saving cable installation and fast processing; Sea water-resistant for onshore and offshore
applications; FRNC = Flame Retardant Non Corrosive
– Reduction of flame-propagation and
density and toxicity of smoke gases
in the event of fire
– Minimisation of damage to buildings
and production facilities
– Safety for staff and in
areas with high density of people; The copper wrapping of the screened D
version protects against electromagnetic
interference
- Torsion resistant, Cold flexible and Oil resistant for drip loops
- Halogen-free, Highly flame retardant, Low smoke density
- EMC/Screened
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
ÖLFLEX® TORSION D FRNC – screened | |||||||
Lapp 1150111 | ÖLFLEX TORSION D FRNC 4 x 2 x 0,5 | ||||||
4 x 2 x 0,5 | 11,9 | 71.0 | 205 | ||||
Lapp 1150115 | ÖLFLEX TORSION D FRNC 12 x 2 x 0,5 | ||||||
12 x 2 x 0,5 | 18,3 | 188.0 | 518 | ||||
Lapp 1150121 | ÖLFLEX TORSION D FRNC 4 x 2 x 0,75 | ||||||
4 x 2 x 0,75 | 12,7 | 90.0 | 232 | ||||
Lapp 1150125 | ÖLFLEX TORSION D FRNC 12 x 2 x 0,75 | ||||||
12 x 2 x 0,75 | 19,8 | 258.0 | 603 | ||||
Lapp 1150221 | ÖLFLEX TORSION D FRNC 18 G 0,75 | ||||||
18 G 0,75 | 15,2 | 180.0 | 402 | ||||
Lapp 1150228 | ÖLFLEX TORSION D FRNC 50 G 0,75 | ||||||
50 G 0,75 | 24,9 | 470.0 | 1079 |
Application range
- For fixed and flexible installations, as well as for applications with torsional movements (e.g. machinery, wind turbines)
- Very suitable for installation in the drip loop, between the rotating nacelle and the stationary windmill tower, to connect the generator to the control units
Benefits
- The special design reliably compensates for the permanent torsional drip loop movements inside the wind turbine between the nacelle and the tower
- The high flexibility and good dismantling
and stripping properties enable easy space-
saving cable installation and fast processing - Sea water-resistant for onshore and offshore
applications - FRNC = Flame Retardant Non Corrosive
– Reduction of flame-propagation and
density and toxicity of smoke gases
in the event of fire
– Minimisation of damage to buildings
and production facilities
– Safety for staff and in
areas with high density of people - The copper wrapping of the screened D
version protects against electromagnetic
interference
Product Make-up
- Extra-fine wire conductor made of bare copper
- Core insulation: polyolefin compound
- Core connection optimised for high torsion requirements, twisted in layers
- Optional screening (D): wrapped with braided tinned-copper wires
- Outer sheath: special compound, halogen-free, black (RAL 9005)
Norm references / Approvals
- Use of leading, European metric stranded conductors according to the IEC scale for conductor nominal cross-sections in mm² according to IEC 60228/VDE 0295, braided conductor class 6 (tinned): For converting to AWG, odd-numbered nominal AWG cross-sections must be excluded. The next lowest nominal AWG conductor cross-section in mm² must then be allocated to the metric nominal conductor cross-section in mm² (according to IEC 60228) (please refer to the technical catalogue appendix T16). This is to ensure that the normative current rating defined by the nominal AWG conductor cross-section does not exceed the physical/real current rating defined by the nominal IEC conductor cross-section that is actually used
- Cable type certifications: UL AWM style 21288 by UL acc. UL standard as well as cUL AWM II A/B by UL acc. CSA AWM standard
- Fire behaviour:
– Halogen-free (IEC 60754-1)
– No corrosive gases (IEC 60754-2)
– Low smoke density (IEC 61034-2)
– Flame-retardant (IEC 60332-1-2)
– No fire propagation (IEC 60332-3-24
and IEC 60332-3-25) - Oil-resistant according to EN 60811-404
and UL OIL RES I and UL OIL RES II - UV-resistant according to ISO 4892-2 and ozone-resistant according to EN 50396
Product features
- Torsion-resistant up to ±150°/m
- Good weather, abrasion, temperature and UV-resistance
- Resistant to oils
- Halogen-free and highly flame-retardant
- Depending on the quantity, customised designs are also possible upon request
Core identification code | Power and control cables: Colour-coded in accordance with VDE 0293-308, refer to Appendix T9 From 6 cores: black with white numbers Paired signal cables: DIN 47100 |
Classification | ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable |
Conductor stranding | Extra-fine wire acc. to VDE 0295, class 6/ IEC 60228 class 6 |
Torsion movement in WTG | TW-0 & TW-2, refer to Appendix T0 |
Minimum bending radius | Flexible use: 10 x outer diameter Fixed installation: 6 x outer diameter |
Nominal voltage | According to IEC/VDE: U0/U 0.6/1 kV ac Operating voltage in accordance with UL: 1000V |
Test voltage | C/C: 4000 V C/S: 2000 V |
Protective conductor | G = with GN-YE protective conductor X = without protective conductor |
Temperature range | Flexible use: -40°C to +90°C (UL +80°C) Fixed installation: -40°C to +90°C (UL +80°C) |