Product Description
ÖLFLEX® CLASSIC 135 CH BK 0,6/1 kV
ÖLFLEX® SERVO FD 781 CY
H05RN-F
Rubber cable for handheld devices and chains of decorative lights
Type-compliant versions <HAR>-certified with <HAR> testing and certification mark for accelerated granting of approvals if final application of cable is within the European CENELEC area
- Oil-resistant
SKU: 100000054
Categories: CABLES & ACCESSORIES, Harsh conditions, Power and control cables, Rubber cables
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||
---|---|---|---|---|---|---|---|
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) | ||||
Lapp 1600250 | H05RN-F 2 X 0,75 | ||||||
2 X 0,75 | 5,7 – 7,4 | 14.4 | 80 | ||||
Lapp 1600252 | H05RN-F 3 G 0,75 | ||||||
3 G 0,75 | 6,2 – 8,1 | 21.6 | 95 | ||||
Lapp 16002583 | H05RN-F 4 G 0,75 | ||||||
4 G 0,75 | 6,8 – 8,8 | 28.8 | 105 | ||||
Lapp 1600251 | H05RN-F 2 X 1,0 | ||||||
2 X 1,0 | 6,1 – 8 | 19.2 | 95 | ||||
Lapp 1600253 | H05RN-F 3 G 1,0 | ||||||
3 G 1,0 | 6,5 – 8,5 | 28.8 | 115 |
Application range
- According to HD 516/VDE 0298-300: for supplying devices in households, kitchens or offices under light mechanical stress; handheld inspection lamps
- According to HD 516/VDE 0298-300: provided the maximum conductor temperature of +60 °C, the maximum outer sheath surface temperature of +50 °C and the lack of ozone resistance are taken into account, suitable for permanent use outdoors with conventional mechanical stress
Benefits
- Type-compliant versions <HAR>-certified with “<HAR>” testing and certification mark for accelerated granting of approvals if final application of cable is within the European CENELEC area
Product Make-up
- Bare copper wire according to HAR
- Core insulation: rubber compound type EI 4
- Outer sheath: rubber compound, type EM2
Norm references / Approvals
- <HAR> cable type certified acc. EN 50525-2-21
Product features
- Flame-retardant according IEC 60332-1-2
- Oil-resistant according to EN 60811-404
Core identification code | Coloured according to HD 308 |
Classification | ETIM 5.0 Class-ID: EC001578 ETIM 5.0 Class-Description: Flexible cable |
Conductor stranding | Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5 |
Minimum bending radius | 4 to 8 xOD* (HD 516) |
Nominal voltage | U0/U: 300/500 V |
Test voltage | 2000 V |
Protective conductor | G = with GN-YE protective conductor X = without protective conductor |
Current rating | According to IEC 60364-5-52/ VDE 0298-4 HD 516/VDE 0298-300 |
Temperature range | Flexible use: -25°C to +60°C |