Product Description
UNITRONIC® BUS PB TORSION
S/A cable: shielded, M12 connector/socket on free conductor end
UNITRONIC® BUS CAN
- CAN = Controller Area Network
SKU: 100000324
Categories: CABLES & ACCESSORIES, Cables for bus system CAN UL/CSA-approved, Characteristic impedance: 120 ohm, Data communication systems
Article List
Product description
Technical Data
Lapp No. | Product Name | Datasheet / Product video | Request Quote | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Article designation | Number of pairs/conductor cross section (mm²) | Outer diameter (mm) | Conductor resistance | Copper index (kg/km) | Weight (kg/km) | ||||||
for fixed installation | |||||||||||
Lapp 2170260 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 1 x 2 x 0,22 | 5.7 | 186.0 | 16.7 | 42.0 | ||||||
Lapp 2170261 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 2 x 2 x 0,22 | 7.6 | 186.0 | 34.8 | 68.0 | ||||||
Lapp 2170263 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 1 x 2 x 0,34 | 6.8 | 115.0 | 25.0 | 55.0 | ||||||
Lapp 2170264 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 2 x 2 x 0,34 | 8.5 | 115.0 | 46.4 | 88.0 | ||||||
Lapp 2170266 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 1 x 2 x 0,5 | 7.5 | 78.0 | 41.6 | 90.0 | ||||||
Lapp 2170267 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 2 x 2 x 0,5 | 9.6 | 78.0 | 59.4 | 106.0 | ||||||
Lapp 2170269 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 1 x 2 x 0,75 | 8.7 | 52.0 | 52.7 | 108.0 | ||||||
Lapp 2170270 | UNITRONIC BUS CAN | ||||||||||
UNITRONIC® BUS CAN | 2 x 2 x 0,75 | 11.5 | 52.0 | 80.6 | 142.0 |
Application range
- Fixed installation
Product Make-up
- 0.22 + 0.34 + 0.5: bare stranded conductor, 7-wire
0.75: bare stranded conductor, fine-wire - Colour-coded in accordance with DIN 47100
- Copper braid
- PVC sheath
- Colour: violet (RAL 4001)
Norm references / Approvals
- Standardised internationally in ISO 11898
- UL/CSA type CMX (UL 444)
Product features
- Maximum bit rate: 1 Mbit/s for 40 m
segment length - Larger conductor cross-section is necessary with increasing length. Refer to the table below (reference values from ISO 11898).
- ISO 11898 makes recommendations for the segment length, cable cross section and bit rate
- Flame-retardant according IEC 60332-1-2
Mutual capacitance | (800 Hz): max. 40 nF/km |
Peak operating voltage | (not for power applications) 250 V |
Conductor resistance | (loop): max. 186 ohm/km |
Minimum bending radius | Fixed installation: 8 x outer diameter |
Test voltage | Core/core: 1500 V rms |
Temperature range | Fixed installation: -30°C to +80°C Flexing: -5°C to +70°C |
Characteristic impedance | 120 ohm |